Welcome !

Guangzhou Hiseer Air conditioning Co.,Ltd

企业会员1YEAR

Guangzhou Hiseer Air conditioning Co.,Ltd

Country:Nationwide,China

Business:

Keymark certified R32 EVI inverter heat pump RS15V/L

PriceInquire

Brand
Hiseer
Quantity
Min. Order
5
Country
Guangdong,China
Recommended For You
品牌:
Hiseer
Model
RS15V/L
Origin
Made In China
Label
R32 heat pump , inverter heat pump , hot water heat pump

R32 making up 50% of the  R410A refrigerant , R32 has a GWP of 675 (one third that of R410A), is highly energy efficient and is easy to recycle. Plus, the volumetric capacity of R32 is around 20% higher than that of R410A, which means system refrigerant volumes are lower. R32 is a single component refrigerant, meaning it is easier to reuse and to recycle. It is also relatively inexpensive to produce, is easier to handle because it doesn’t separate and utilises familiar technology, keeping costs similar.

R32: The Benefits:

Low GWP of 675

High efficiency refrigerant

F–Gas phasedown compliant

Less refrigerant volume requirement compared to R410A

Affordable & readily available

A single component refrigerant

Easy to handle, reuse and recycle

Used in our newest, state–of–the–art products

 

With a Hiseer R32 EVI inverter heat pump. you still get the performance and efficiencies needed for the buildings, using refrigerants and equipment that delivers a much lower GWP overall.

 

Model NumberRS15V/L
Heating performanceMin. Nominal Max.
Heat output/Power consumption/COP at A7/W35℃ kW4.90/1.14/4.3015.28/3.27/4.6717.80/4.05/4.40
Heat output/Power consumption/COP at A2/W35℃ kW8.00/2.22/3.6013.53/3.27/4.1415.70/4.03/3.90
Heat output/Power consumption/COP at A-7/W35℃ kW5.60/2.34/2.399.75/3.68/2.6511.30/4.52/2.50
Heat output/Power consumption/COP at A-10/W35℃kW5.50/2.43/2.269.67/3.84/2.5111.15/4.72/2.36
Heat output/Power consumption/COP at A-15/W35℃kW4.90/2.51/1.958.6/3.96/2.1710.00/4.93/2.03
Heat output/Power consumption/COP at A7/W45℃  kW9.00/2.82/3.1915.58/4.40/3.5418.20/5.47/3.33
Heat output/Power consumption/COP at A2/W45℃ kW8.03/2.77/3.0013.80/4.48/3.0716.00/5.52/2.90
Heat output/Power consumption/COP at A-7/W45℃  kW6.10/2.99/2.0410.58/4.66/2.2712.30/5.86/2.10
Heat output/Power consumption/COP at A-10/W45℃kW5.70/3.03/1.889.80/4.70/2.0911.30/5.68/1.99
Heat output/Power consumption/COP at A-15/W45℃kW5.00/2.98/1.688.77/4.70/1.8710.20/5.67/1.80
Heat output/Power consumption/COP at A7/W55℃  kW5.20/2.02/2.5715.80/5.51/2.8618.40/6.81/2.70
Cool output/Power consumption/EER at A35/W7℃kW4.14/1.51/2.7511.25/4.43/2.5413.08/5.45/2.40
Nominal running current at A7/W35A5.43
Aux. heaterKW 6 
Max operating current (aux. heater running)A11.2 (19.9)
Max power consumption (aux. heater running)KW 6.6 (12.6) 
Power Supply 380-415V//3phase/50Hz
Compressor Panasonic EVI twin rotary
Condenser Brazed plate heat exchanger
Nominal flow heating mediumm3/h2.58
Internal pressure drop at nominal flowkPa10
Nominal air flowm3/h5000
Nominal fan output W220
Max outlet heating medium temperature58
Refrigerant R32 filling weightkg2.9
Dimensions (HxWxD)mm1172 x 1060 x 420 
Pipe connector G1' external thread
Net Weightkg140
Operating ambient temp. rangeHeating -25~35
DHW -25~43
Cooling 10~45
Sound power level LWAdB(A)69
The above data is tested by EN14511. A7/W35℃ means air temp. 7℃,outlet water temp. 35℃ 
The Sound power level is tested by EN12102    

 


 

Contacts
Company Name
Guangzhou Hiseer Air conditioning Co.,Ltd
Name:
Mr. He zhenwen
Telephone
86-20-61171400
Address
Operational Address
xicheng industry zone,renhe town,guangzhou china
peakexporter.com温馨提示

本网页所展示的有关【Keymark certified R32 EVI inverter heat pump RS15V/L】的信息/图片/参数等由的会员【Guangzhou Hiseer Air conditioning Co.,Ltd】提供,由peakexporter.com会员【Guangzhou Hiseer Air conditioning Co.,Ltd 】自行对信息/图片/参数等的真实性、准确性和合法性负责,本平台(本网站)仅提供展示服务,请谨慎交易,因交易而产生的法律关系及法律纠纷由您自行协商解决,本平台(本网站)对此不承担任何责任。您在本网页可以浏览【Keymark certified R32 EVI inverter heat pump RS15V/L】有关的信息/图片/价格等及提供【Keymark certified R32 EVI inverter heat pump RS15V/L】的商家公司简介、联系方式等信息。

在您的合法权益受到侵害时,请您致电,我们将竭诚为您服务,感谢您对peakexporter.com的关注与支持!