Product Description
Wires and cables that are hard to catch on fire and have the ability to prevent or delay the spread of fire are usually referred to the wires and cables that can be tested by GB/T18380.3 (equivalent to IEC60332-3).TESTECH Fire and Impact resistance Tester is degsigned and produced accordance with the BS6387-2013 and GB/T 19216 to the latest standards requirements. Because two kinds of tests can be carried out on the one electrical control box, this tester could savings much cost for customers.
All kinds of experiments can be freely selected on the touch screen.
Model:FTech-IEC60331-12
Standards
• IEC 60331 part 12
• IEC 60331 part 31
• IEC 60331-1
• BS6378:2013 Performance requirements for cables required to maintain circuit integrity under fire conditions
Main Features
1, The burner is a belt type propane blowtorch with a Venturi mixer, and the burner nozzle is length 500mm, width 15mm.
2, Those burning holes are staggered into 3 rows, and the front width is 15mm, holes diameter is 1.32mm and these holes center distance is 3.2mm;
3, Double flow meter and pressure regulator at the inlet.
4, Air flow is (80± 5) L/min,and Propane flow is (5 ±0.25) L/min;
5, Diameter of the K-type thermocouple is 2mm,
6, One end of the specimen holder is equipped with a clamp to fix the sample, and the other end is convenient for heat transfer along the longitudinal specimen;
7, An inner diameter of the sample supporting metal rings is 150mm, and the cross-sectional diameter of the ring is 10 ± 2mm.
8, Equipped with two 1.5mm thermocouple; horizontal 45mm far away from the burner;Flame temperature is 750+50 °C; according to BS6387 standard temperature 950 ℃;
9, Control system is designed with Intelligent detection, during the test when short circuit occurs, automatic alarm and turn off the ignition.
10, PLC and touch screen control system, and automatically record store test data.
11, The circuit current fuse is 2A;
12, Samples impose power AV 100V~1000V adjustable;
13, The test time can be set freely, the standard recommending time is 90min,
14, 27m ³ combustor is optional.
Impact test device:
1, Stainless steel impact structure;
2, Impact cone is a round steel bar diameter of 25mm and length 600mm.
3, Impact cone at 60-degree angles free fall,
4, motor-driven rods hammer shock action cycling.
5, Impact cycles is 30±2Sper time
6, Ribbon burners ( the same one with spray test) (used with fire-resistant combustion tester)
7, test temperature 600~1000 ° (a grade 650 °, b grade 750 ° and c,d 950 ° )
8, The diameter of K-type thermocouple is 2mm.
9, The circuit current of each phase is 0.25A.
Specifications
Model | FTech-IEC60331-12 |
Size | 1,600(W)×850(D)×1,650(H)mm |
Control table | 600(W)×750(D)×1,200(H)mm |
Power | AC 380V 3-phase, 50/60Hz, 30A |
Weight | 100kg |
Exhaust | Min 15㎥/min |
Inquire
Inquire
CN ¥1.00
Inquire
Inquire
CN ¥340.00
Inquire
Inquire
Inquire
Inquire
本网页所展示的有关【Wire Fire and Impact Resistance Test Machine】的信息/图片/参数等由的会员【TESTech Instrument Technologies Co., Ltd.】提供,由peakexporter.com会员【TESTech Instrument Technologies Co., Ltd. 】自行对信息/图片/参数等的真实性、准确性和合法性负责,本平台(本网站)仅提供展示服务,请谨慎交易,因交易而产生的法律关系及法律纠纷由您自行协商解决,本平台(本网站)对此不承担任何责任。您在本网页可以浏览【Wire Fire and Impact Resistance Test Machine】有关的信息/图片/价格等及提供【Wire Fire and Impact Resistance Test Machine】的商家公司简介、联系方式等信息。