PeakExporterBuilding materials, architectural hardware, lighting, fit-out products, and construction supply lines for export buyers.
Reciprocating Explosion-Proof Volatile Chemical Toxic Corrosive Explosive Petrochemical Gas Diaphrag
Security & Protection

Reciprocating Explosion-Proof Volatile Chemical T | RFQ Sourcing Details

Security & Protection · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryGas Detectors
Unitset
MuteNot Mute
TypeV Z L D Type
ModelGL2-50/7-160
MediumH2 Gas
OriginChina
MaterialStainless Steel
CategorySecurity & Protection
AvailabilityInquiry required
Updated2026-05-27

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Security & Protection. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

V type diaphragm compressor for high purity gases type inlet pressure MPa(G) outlet pressure MPa(G) flow rate N m 3 /h power kW rotate speed r/min 1G3V-40/13-I normal pressure G3V-40/ H-GV3-950/ H-GV3-60/ GV3-100/ GV3-200/ G2.5V-10/200 normal pressure G2.5V-10/ G2.5V-20/ G2.5V-20/ G2.5V-20/ CG2V-5/200 normal pressure G2V-10/13 normal pressure G2V-5/ G2V-8/ G2V-5/ Equipment specifications and requirements 1.1 Location and site conditions: (1) installation location: Indoor (2) : dIIBT4, Explosion protection requirements: Motor dIIBT4, 1.2: Common engineering criteria (1) Cooling water Pressure 3~5 Bar (G) Water inlet temperature ≤ 30ºC (2) Electric 3P/380 VAC/ 50HZ, 1.3 Drive method: Electric motor , Belt drive 1.4 Processing technology and parameter requirements (1)Suction pressure: 7 bar (G) (2) Discharge pressure: 160bar (G) (3) Suction Capacity: 50.

Nm3/h (4) Media: CH4 C2H4 (5) Suction temperature: ≤30 ºC (6) Temperature of water inlet: ≤30 ºC 2 Technical Parameters 2.1 Main Technical Specifications (1) Model: GL2-50/7-160 (2) Type L-type, water-cooling,two-stage Compression (3) Drive method Crank shaft and connecting rod (4) Media : CH4 C2H4 (5)Suction Capacity: 50.

Nm3/h (6) Suction pressure: 7 bar (G) (7) Discharge pressure: 160bar(G) (8) Suction temperature: ≤30 ºC (9)Discharge temperature: ≤45 ºC (10)Lube oil temperature: ≤70 ºC (11) Crank shaft speed: 420r/min (12) Piston stroke: 105 mm (13) Shaft power: ≤9.5.kW (14) Water-inlet temperature: ≤30 ºC (15) Cooling water consumption 1200L/h (16)Lube oil trademark: L-HM -68 L-HM-68# Chemical-Resistant Lube oil (18) :Amount of the first oil: 25.

Kg (19) Transmission method: strap transmission 2.2 Electromotor (1)Model: YB3-160L-4 (2) Power: 15kW (3) Electromotor speed: 1460r/min (4) Supply voltage 380V/50.

Hz (5) Defend exploding grade: dIIBT4 (6) Defend and insulation request: IP55/F 2.2.1 Electromotor (1)Model: YB3-80L-4 (2) Power: 0.75kW (3) Electromotor speed: 1400r/min (4) Supply voltage 380V/50. Hz 2.3 Compressor skid (1) Dimensions: 1700×850×1150mm (2) Weight: 1100 kg 3

Reciprocating | Applications and Buyer Notes

Reciprocating is organized as a sourcing-ready Security & Protection reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-ti

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Gas DetectorsBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
Mute
Not MuteBased on visible page data; confirm exact value in the RFQ.
Type
V Z L D TypeBased on visible page data; confirm exact value in the RFQ.
Model
GL2-50/7-160Based on visible page data; confirm exact value in the RFQ.
Medium
H2 GasBased on visible page data; confirm exact value in the RFQ.
Origin
ChinaBased on visible page data; confirm exact value in the RFQ.
Material
Stainless SteelBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryGas Detectors
Unitset
MuteNot Mute
TypeV Z L D Type
ModelGL2-50/7-160
MediumH2 Gas
OriginChina
MaterialStainless Steel
Warranty1year
TrademarkDSW
Drive ModeElectromagnetic
ApplicationHigh Back Pressure Type
PerformanceLow Noise
Power SourceElectric Motor
ConfigurationStationary
Specification5-950nm3/h
Specifications(1)
Lubrication StyleOil-free
Transport PackageStandard Seaworthy Packing

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

PeakExporter related sourcing paths

Related categories PeakExporter related paths
Related applications PeakExporter related paths
Related solutions PeakExporter related paths

PeakExporter related product samples