HLC-2XT04GG(2P/40A/120VAC)Definite Purpose Contactors

PriceCN ¥6.40

Brand
HONGLI
Quantity
Min. Order
1000 pc
Country
JiangxiJian City,China
Recommended For You
品牌:
HONGLI
Model
2P/40A/120VAC
Origin
Made In China
Label
AC Contactor , Contactor , DP Contactor

1. Applicable Scope

HLC-2XT04GG(2P/40A/120VAC)Definite Purpose Contactor(Follow Defers To DP Contactor),Mainly Is Suitable For 50Hz Or 60Hz, When The AC-8a Use Category Fixed Working Voltage Is 240V Or 277V The Nominal Current Up To The 40A Electric Circuit, Is Suitable For The Starting And The Control Single-Phase Motor (Or Compressor) And Other Single-Phase Loads.Mainly Uses In The Domestic Electric Appliances Profession, Specially In Air Conditioning Profession,Conforms To IEC60947, UL508 and GB14048standard.

2.Type and Meaning

HLC-2XT04GG
Hongli ElectricContactorFactory Bulk Pack2P120VAC40 FLA#14-4 Lug with quad QC
Product Explanation And Main Technical Parameter
TypeHLC-2XT04GG(2P/40A/120VAC) Definite Purpose Contactor
Standard

IEC60947

UL508

Rating of CurrentIe 40AFLA: 40A
Resistive AmpsIth 50ARES: 50A
Rating of Contacts VoltageUe 240/277V240/277/480/600VAC
Rating of Insulation VoltageUi 660V600V
Rating of Coil VoltageUs 110VUs: 120VAC 50/60Hz
Mechanical Life1000,000 Cycle1000,000 Cycle
Electricity life100,000 Cycle250,000 Cycle
Product Explanation

1.Product Description

HLC-2XT04GG Is Suitable To Exchanges 50 Or 60hz, Fixed Working Voltage To 277v, Fixed Operating Current To 50A Single-Phase Load Circuit Control,At Present, Widely Applies To The Single-Phase Mechanical Device Main Circuit As Well As The Single-Phase Air-Conditioner Compressor Control.


2 .The Regular Service Conditon And Installs The Condition
a. In The Surrounding Air Temperature The Limiting Value Is +65 , Gets
Down The Limiting Value Is -25
b. The Installation Site Elevation Does Not Surpass 2000m
c. The Air Pollution Rank Is 2 Levels
d. Installs The Category Is Ii ;
e. Installment Facing The Gradient Does Not Surpass ±5°
f. Not Remarkable Undulation, Impact And Vibration Place.

3 .Main Technical Parameter
a. Contactor Coil Picking Up In 75% ~ 110% Us Reliably
Working, Its Drop Out Voltage In 20% ~ 70%Us
b. Contactor Use Category: Ac-1Ac8a
c. Contactor In With 0.4m Place, Its Noise Below 40db.

4 . Installing Specification And Install Size

a. Installs The Way To Be Fixed For The Screw, Some Two Kinds Install The Size To Choose One Kind Of Size Fitting Surface And The Horizontal Plane Are The Vertical Shape Gradient Are Not Bigger Than ±5°

b. Before The Use Should Inspect The Power Terminal And The Contactor
Quick Connect Whether Inserts Arrives, Is Reliable, Avoids Creating
The Breakdown, Behind Check Off May Electrify Tries .

 

Conforms To The Standard

 

1 Conforms To UL508, IEC60947, GB14048 Standard
2 Approved By UL,CUL,TUV,CE,CCC,Safe Certification and ISO9001 System Certification(SGS)

CCC Certificate Number:  2005010309156761

UL Files Number: E251539

Ordering Request

In Order To Guarantee You Purchase Right, Please Read The Specify Type Before Order.

If You Request As Follows: Nominal Current: 40A, Working Voltage: 240/277V,480V,600V, Pole Number: One Pole Without Shunt, Coil Control Voltage:120V, Wiring Way: Quick Connect, Load Current: Single-Phase Motor Controls Or Heating Load, Packing: 50/Each Box (Factory Packing), With The Cover. Then You May Be Elect The Type : HLC-2XT04GG

IePoleRating of Coil Control VoltageMotor Power
24VAC120VAC208/240VAC277VAC380/400VAC240VAC
40A2PHLC-2XQ04GGHLC-2XT04GGHLC-2XU04GGHLC-2XV04GGHLC-2XW04GG2.5Kw
Instruction Booklet Downloading

HLC-1P,1N,1X,2X,3X,4X series Difinite Purpose Contactor

DownLoad PDF DataSheet
Contacts
Company Name
Hongli Electric Co.,Ltd
Name:
Mr. Liqian Wang
Telephone
86-577-6252655562569016
Address
Operational Address
GOODSPEC Building,Shuangyu Road,Leshang Pioneer Prak,Yueqing Bay Area, Yueqing City ,Wenzhou City, Zhejiang Province,China
peakexporter.com温馨提示

本网页所展示的有关【HLC-2XT04GG(2P/40A/120VAC)Definite Purpose Contactors】的信息/图片/参数等由的会员【Hongli Electric Co.,Ltd】提供,由peakexporter.com会员【Hongli Electric Co.,Ltd 】自行对信息/图片/参数等的真实性、准确性和合法性负责,本平台(本网站)仅提供展示服务,请谨慎交易,因交易而产生的法律关系及法律纠纷由您自行协商解决,本平台(本网站)对此不承担任何责任。您在本网页可以浏览【HLC-2XT04GG(2P/40A/120VAC)Definite Purpose Contactors】有关的信息/图片/价格等及提供【HLC-2XT04GG(2P/40A/120VAC)Definite Purpose Contactors】的商家公司简介、联系方式等信息。

在您的合法权益受到侵害时,请您致电,我们将竭诚为您服务,感谢您对peakexporter.com的关注与支持!